DuoControl must not be used for commercial purposes.
Safety instructions
– The unit may only be installed and repaired by an expert. Experts
are persons who, based on their specialist instruction and train-
ing, their knowledge and experience with Truma products and the
relevant standards, can carry out the necessary work properly and
identify potential hazards.
– Do not connect any electrical appliances or other potential ignition
sources if you can smell gas or if there is a leak in the gas sys-
tem. Close the cylinder valves, have the gas system repaired by
an expert immediately and do not open the cylinder valves in the
meantime.
– The use of upright gas cylinders from which gas is extracted in the
gas phase is mandatory when operating the DuoControl gas pres-
sure regulator. Gas cylinders from which gas is taken in the liquid
phase (e.g. for fork lifts) must not be used, since they would result
in damage to the gas system.
– A gas filter must be installed upstream of the gas pressure regula-
tor inlet to provide reliable protection against dirt / oiling. A set of
operating and installation instructions is supplied with the gas filter.
– High-pressure hoses are mandatory for connecting the gas cyl-
inders to the gas pressure regulator or gas filter. For this, Truma
provides the necessary high-pressure hoses with the most com-
monly used connection variants for European gas cylinders (see
www.truma.com).
EN
22