- The nozzle is partially blocked. Clean it.
The fuse burns out
- The electrical installation is too light. Connect the machine to an installation that has greater Amperage
than the machine. Do not use an extension cable.
The machine vibrates
- Air in the water supply hose. Allow it to escape by running water through the machine while it is
switched off.
- Problems with the water supply. Does it meet the requirements? Do not use an excessively long or thin
hose (min. ½").
- The nozzle is partially blocked. Clean it.
- Water inlet filter is dirty. Clean it
- There is a kink in the hose. Straighten it.
The machine regularly starts and stops by itself
- Pump or spray lance are leaking. Have them repaired or replaced.
The machine starts but does not supply water
- Pump, hose or accessories are frozen. Allow them to thaw and then check them.
- No water supply. Ensure that there is a water supply.
- Filter blocked. Clean the filter.
- Nozzle blocked. Clean the nozzle.
CE – declaration
The undersigned: Euromac bv., Kokosstraat 20, 8281 JC Genemuiden hereby declares that the
electrical high-pressure cleaner – 230V known under the brand name EUROM, type Force 2200
meets the requirements of the Machinery Directive 2006/42/EC and the EMC Directive 2014/30/EU and
meets the following standards:
EN 60335-1:2012
EN 60335-2-79:2012
EN 62233:2008
Genemuiden, 14-10-2016
W.J. Bakker, alg. dir.