Figure 6B – R (REVERSE) (Counter-Clockwise) Switch
Position
7. Release the ON/OFF switch and with dry hands
unplug the machine.
Set-Up and Operation
WARNING
Set up and operate the power drive according to
these procedures to reduce the risk of injury from
electric shock, entanglement, striking, crushing and
other causes, and to help prevent power drive dam-
age.
Use an appropriate support device per these instruc-
tions. Sup port devices im prove control and reduce
the risk of striking, crushing, and/or other injuries.
When using a support device other than the supplied
support arm, the support device must react against
the gear housing or fan housing. Support devices
contacting the motor housing or handle may damage
these parts or increase the risk of injury.
Always firmly hold the power drive when threading
or backing die head off the pipe to resist use forces,
regardless of support device use. This will reduce
the risk of striking, crushing and other injuries.
Do not wear gloves or loose clothing. Keep sleeves
and jackets buttoned. Loose clothing can become
entangled in rotating parts and cause crushing and
striking injuries.
Properly support pipe. This will reduce the risk of
falling pipe, tipping and serious injury.
Do not use a power drive without a properly oper-
ating ON/OFF switch and F/R slide switch.
One person must control both the work process
and the ON/OFF switch. Do not operate with more
than one person. In case of entanglement, the oper-
ator must be in control of the ON/OFF switch.
1. Check work area for:
• Adequate lighting.
• Flammable liquids, vapors or dust that may ignite.
If present, do not work in area until sources have
been identified and corrected. The power drives are
not explosion proof and can cause sparks.
999-999-476.09_REV. F
600-I/690-I Power Drives
• Clear, level, stable, dry location for all equipment
and operator.
• Good ventilation. Do not use extensively in small,
enclosed areas.
• Properly wired electrical outlet of the correct voltage.
If in doubt, have outlet inspected by a licensed elec-
trician.
• Clear path to electrical outlet that does not contain
any potential sources of damage for the power cord.
2. Inspect the pipe to be threaded and associated fittings
and confirm that the selected power drive is a correct
tool for the job. See Specifications. Do not use to
thread anything other than straight stock.
Equipment for other applications can be found in the
Ridge Tool catalog, online at RIDGID.com or by call-
ing Ridge Tool Technical Service in the U.S. and
Canada at (800) 519-3456.
3. Make sure equipment to be used has been properly
inspected.
4. Properly prepare the pipe as needed. Make sure the
pipe is squarely cut and deburred. Pipe cut at an
angle can damage the dies while threading or cause
difficulty engaging the die head.
Installing Die Heads
5. Installing 1
1
/
" or 2" Die Head or Adapter in 690-I:
2
a. Make sure ON/OFF switch is released and power
drive is unplugged.
b. Rotate the drive ring counter-clockwise to open
the retaining mechanism. Fully insert the die head
or adapter (if required) spline end into the power
drive (Figure 7).
c. Release the drive ring and confirm that the die
head/adapter is secure.
d. Reverse process to remove.
OPEN
Drive
Ring
Figure 7 – Retaining Mechanism, Drive Ring in the
Open/Closed Position
Closed
Open