DOMITOR DM/DB
Installation and connections
3.3.b - Electric hood connection
Concerning electric hood connection, follow the instruc-
tions supplied with the hood.
3.3.c - Unipotential connection (Fig 7)
The equipment shall be inserted in a unipotential system,
whose effectiveness shall be verifi ed according to the
rules being in force.
A cascade connection shall be carried out among the
various oven components by using the screw (1) placed
on the rear oven side.
3.4 - OVEN POSITIONING (Fig 8)
The oven shall not be installed closed to infl ammable
walls such as furniture, partition walls, matchboar-
ded coatings etc... A safety range of at least 20 cms
from lateral and rear oven sides should be kept. No
infl ammable fl ooring shall be utilized to install the
oven on it.
• The oven shall be positioned on the fi nal area following
the indications reported in fi gure 8, because they
indicate the minimum distances required to allow the
oven correctly to function.
• Fix the oven position by braking the rear wheels.

3.5 - FIRST STARTING

Once the oven is installed and before starting it,
carefully clean its inner part as well as refractory
surface as explained in "Maintenance" chapter, also
make sure neither foreign nor infl ammable bodies
are inside the oven.
• Turn on the oven as indicated in "Functioning" para-
graph and set the temperature of both crown plate and
bedplate at 300°C, making sure the set temperature
is reached as well as the different options depending
upon the concerned model are functioning.
DANGER
DANGER
FIG. 7
FIG. 8
GB - 15