KSB BOAX-B Instructions De Service page 31

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

7.2.2
Flanging dimensions
Connection to the piping.
Piping flanges must match the following dimensions.
Ø2a
Ø6
Ø2a: max. allowable diameter on flange face
Ø2b: external diameter of the pipe when fitting loose plate flange with
lapped pipe end
Ø3: allowed minimum diameter on flange face
Ø4: minimum diameter at 10mm from the flange face
Ø5: minimum diameter at 20mm from the flange face
Ø6: allowed minimum diameter of raised face
DN
NPS
ø2a
ø2b
40
1 ½
54
49
50
2
63
61
65
2 ½
80
77
80
3
93
89
100
4
116
115
125
5
141,5
140
150
6
170,5*
169
200
8
222*
220
250
10
276,5*
273
300
12
327,5*
324
350
14
361
356
400
16
412
407
450
18
463
457
500
20
515
508
600
24
617
610
650
26
668
700
28
718
750
30
770
800
32
820
900
36
924
1000
40
1027
* Please check that the body is well centered between the tie--rod
7.2.3
Interface between valve and pipe flanges
Correct fitting except T6 bodies
Metallic intermediate insertion flange
no direct contact
no gasket
with the
expansion joint
In case of coated pipe (hard rubber, concrete or Teflon for
example), coating hardness and flanges detailed dimensions
shall be given to KSB for acceptance.
In case of fitting between polyethylene flanges:
- - Authorized fitting between flanges with flat faces
- - Not authorized fitting between flanges with grooved faces
Ø3
10 mm
20 mm
Ø5 Ø4
Ø2b
ø3
ø4
ø5
ø6
32
77
33
86
55
13
107
71
50
121
90
74
40
141
119
107
87
171
144
134
120
196
196
189
178
250
249
243
234
306
297
291
283
358
326
321
314
399
370
366
358
452
422
416
409
505
470
464
457
558
566
560
554
664
620
614
608
723
671
666
660
773
717
711
705
830
769
764
758
880
869
864
859
987
970
965
960
1094
no rubber coated flange
T5 type body
7.3 Handling
Handling means may be necessary to install large sizes valves.
They must be used as shown.
VALVE WITH MOTORIZATION
CORRECT
CORRECT
BOAX- -B Mat- -P
HORIZONTAL VALVE
CORRECT
Neck extension and body supports may have been delivered
separately from the valve. They must be mounted onto the
valve before fitting it between flanges
FORBIDDEN
FORBIDDEN
FORBIDDEN
31