Installation - ETATRON D.S. BH3-V Notice D'installation, Emploi Et Entretien

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

3.0 - INSTALLATION

a. - Install the pump in a dr y place and well away from sources of heat and, in any ca se, at env ironmental tem-
peratures not exce eding 40°C. The
bearing in mind that it must always remain in a liquid state.
b. - Carefully observe the regu
When the supply cable i s devoid of a plug, the equipment should be connected to the supply mains by
means of a single-pole circuit breaker having a minimum distance o f 3 mm
accessing any of the electrical parts, make sure that all the supply circuits are open.
c. - Locate the pump as shown in fig. 5 bearing in mind that it may be installed either below or abov e the level of
the liquid to be d osed, though the level difference should not exceed 2 meters. In case of liquids that genera-
te aggressive vapours, don't install the pump above the storage tank unless the latter is ermetically sealed.
Users can modify the rpm of the motor of the peristaltic pump
by means a potentiometer adjustable by a screwdriver supplied
in the package.
minimum operating temperature depends on the li quid to be pumped,
lations in f orce in the va rious countries as r egards electrical installations (Fig.4).
• 14 •
between th e contacts. Before
Fig. 4

Publicité

Table des Matières
loading

Table des Matières