1.5 - TOXIC AND/OR DANGEROUS LIQUID DOSAGE

To avoid risk from contact with the hazardous liquids or toxic fumes, always adhere to the notes in this instruction
manual:
• Follow the instructions of the dosing liquid manufacturer.
• Check the hydraulic part of the pump and use it only if it is in perfect condition.
Use only the correct ma terials for the tu bing, valves and seals to suit the
shield the tubing with PVC conduit.
Before disco
nnecting the metering pump, make sure to flush o
proper reagent liquid.

1.6 - ASSEMBLING AND DISMANTLING THE PUMP

1.6.1 - ASSEMBLY
All metering pumps are normally supplied fully assembled. For greater clarity, please consult the explod ed view
of the pump append ed at the end of t he manual, which s hows all the pu mp details and a complete overview of
all the pump
components. These drawings are in any
to be re-ordered.

1.6.2 - DISMANTLEMENT

Proceed as follows before you dismantle the pump or before performing any other operation on it:
1.
Disconnect the plug from the main s or by means of a o nnipolar switch with 3 mm minimum distance between
the contacts. (Fig. 4).
2. Relieve all the pressure from the injection tube.
ut and n eutralize the pump head with the
case quite indispensable whenever defective parts have
• 11 •
liquid to b e dosed; where possible