Voltmeter/Ammeter Help Displays - Miller XMT 425 CC/CV Auto-Line Mode D'emploi

Table des Matières

Publicité

6-3. Voltmeter/Ammeter Help Displays

OM-234 196 Page 22
V
A
HE.L P−1
V
A
HE.L P−2
V
A
HE.L P−3
V
A
HE.L P−5
V
A
HE.L P−6
V
A
HE.L P−8
.
All directions are in reference to
the front of the unit. All circuitry
referred to is located inside the
unit.
Help 1 Display
Indicates a malfunction in the prima-
ry power circuit. If this display is
shown, contact a Factory Authorized
Service Agent.
Help 2 Display
Indicates a malfunction in the ther-
mal protection circuitry. If this display
is shown, contact a Factory Autho-
rized Service Agent.
Help 3 Display
Indicates the left side of the unit has
overheated. The unit has shut down
to allow the fan to cool it (see Section
3-4). Operation will continue when
the unit has cooled.
Help 5 Display
Indicates the right side of the unit has
overheated. The unit has shut down
to allow the fan to cool it (see Section
3-4). Operation will continue when
the unit has cooled.
Help 6 Display
Indicates operation at maximum in-
put current. The unit has a maximum
allowable input current limit. As the
line voltage decreases, the required
input current increases. If the line
voltage is too low, the output power
is limited by the input current. When
this limit is reached, the unit automat-
ically reduces output power to con-
tinue operation. If this display is
shown, have a qualified electrician
check the input voltage.
Help 8 Display
Indicates a malfunction in the sec-
ondary power circuit of the unit. If this
display is shown, contact a Factory
Authorized Service Agent.