Alarm
Fault
System filling procedure not
E25
completed
E27
Failure test gas
E28
Valve has failed to close/open.
Core probe not inserted in the
E29
food
E80
1 Chamber inverter anomaly
E81
2 Chamber inverter anomaly
1 chamber combustion control
E82
anomaly
2 chamber combustion control
E83
anomaly
1 chamber incorrect configura-
E84
tion
2 chamber incorrect configura-
E85
IT
tion
GB
"Cleaning timer" timeout warn-
W01
ing
DE
FR
Chamber
W02
check warning
ES
WARNING!
Cleaning was interrupted by
cleaning
means of the START/STOP
interrupted
button
ATTENTION!
call the engi-
A year has elapsed since the
neer to check
last CO and CO2 fumes check
the CO2 and
CO emissons
English
Remedy
Check the position of the pipe
and the level of the sanitizer in
the container; if necessary, top
it up and re-launch the automat-
ic cleaning cycle.
Inform the after-sales service
Press the "Reset" button
Insert the core probe
Inform the after-sales service
Inform the after-sales service
Inform the after-sales service
Inform the after-sales service
Inform the after-sales service
Inform the after-sales service
Carry out cleaning before timer
timeout.
Check the chamber limescale
limescale
quantity
quantity and descale if neces-
sary.
Restart cleaning or carry out an
emergency rinse.
Inform the after-sales service
- 52 -
Notes
If the problem persists, call
the after-sales service
Inform the after-sales service
If the problem persists, call
the after-sales service
The oven's functions are ena-
bled so cooking cycles can be
carried out
The oven's functions are disa-
bled so no cooking cycles can
be carried out
The oven's functions are disa-
bled so no cooking cycles can
be carried out
The oven's functions are disa-
bled so no cooking cycles can
be carried out
The oven's functions are disa-
bled so no cooking cycles can
be carried out
The oven's functions are disa-
bled so no cooking cycles can
be carried out
The oven's functions are disa-
bled so no cooking cycles can
be carried out
It is possible to carry out a
cooking cycle when residual
time has elapsed
It is not possible to carry out
cooking cycles until a com-
plete washing cycle or emer-
gency rinse cycle has been
carried out
To clean the parts inside the
technical compartment (be-
hind the door) it is necessary
to use abrasion and cut resist-
ant gloves