5.0 Electrical connections

All electrical connections must be
done by a qualified electrician in compliance with all
local codes and ordinances. Failure to comply may
result in serious injury.
Mains connection and any extension cords used must
comply with applicable regulations.
The mains voltage must comply with the information
on the machine license plate. The dust collector comes
with a plug designed for use on a circuit with a
grounded outlet.
Keep in mind that a circuit being used by other
machines, tools, lights, heaters, etc. at the same time
will add to the electrical load. A dedicated circuit to
the dust collector will offer best results since dust
collectors are generally used while other tools are
running.
Before connecting to power source, be sure switch is
in off position.
5.1 GROUNDING INSTRUCTIONS
This appliance must be grounded. If it should
malfunction or breakdown, grounding provides a path
of least resistance for electric current to reduce the
risk of electric shock. This appliance is equipped with
a cord having an equipment-grounding conductor and
grounding plug. The plug must be inserted into an
appropriate outlet that is properly installed and
grounded in accordance with all local codes and
ordinances.
Improper connection of the
equipment-grounding conductor can result in a risk
of electric shock. Check with a qualified electrician or
service person if you are in doubt as to whether the
outlet is properly grounded. Do not modify the plug
provided with the appliance – if it will not fit the
outlet, have a proper outlet installed by a qualified
electrician.
The conductor with insulation having an outer surface
that is green with or without yellow stripes is the
equipment-grounding
conductor.
replacement of the electric cord or plug is necessary,
do not connect the equipment-grounding conductor
to a live terminal.
Repair or replace damaged or worn cord immediately.
Make sure that the appliance is connected to an outlet
having the same configuration as the plug. No adapter
should be used with this appliance. If the appliance
must be reconnected for use on a different type of
electric circuit, the reconnection should be made by
qualified service personnel; and after reconnection,
the appliance should comply with all local codes and
ordinances.
6.0 Operations
6.1 Start/stop
Press green start button (A, Figure 15) to start dust
collector. Press red stop button (B) to stop.
The stop button (B) remains engaged after being
pushed. To restart dust collector, rotate stop button
clockwise to disengage.

6.2 Remote controller

The RF (radio frequency) remote controller operates
on 2 AAA batteries (included). The batteries will need
replacing periodically. The remote controller has an
effective range up to approximately 50 feet (15
meters).
Press the + or – button to select desired timer setting:
2, 4, 6 or 8 hours. The dust collector will stop
automatically at end of selected period. For
continuous operation (no timer) select infinity ( )
position.
If
repair
or
6.2.1 Remote controller reset
If the remote controller begins to function improperly,
it should be cleared and reset.
To clear the remote controller, press and hold reset
button (C, Figure 15) for 3 seconds until receiver
"beeps" 3 times.
To reset the controller:
1.
13
Figure 15
Figure 16
Press reset button (C, Figure 15) for 1 second until
receiver "beeps" once.