Description
717511
Canister collection bag for JCDC (package of 5)
717531
Drum collection bag for JCDC-3.0-T (package of 5)
9.0 Troubleshooting the JCDC-3.0-T
9.1 Electrical and motor problems
Symptom
Motor will not start.
Motor will not start: fuse
blows or circuit breaker
trips.
Motor overheats.
Motor stalls, resulting in
blown fuses or tripped
circuit.
Loud noise or vibrations
coming from machine.
Remote controller fails
to activate machine.
*WARNING: Some corrections may require a qualified electrician.
Table 2
Possible Cause
No incoming current.
Safety key missing from switch.
Low voltage.
Open circuit in motor or loose
connection.
Faulty start switch.
Faulty start capacitor.
Faulty motor.
Too many machines on shared circuit.
Short circuit in line cord or plug.
Short circuit in motor or loose
connections.
Incorrect fuse or circuit breaker in
power line.
Motor overloaded.
Air circulation through motor is
restricted.
Motor overloaded.
Short circuit in motor or loose
connections.
Low voltage.
Incorrect fuse or circuit breaker in
power line.
Loose fasteners.
Motor fan is hitting the cover.
Impeller is damaged.
Stop button still engaged.
Batteries drained.
Remote needs resetting.
15
Correction*
Check connections at plug or circuit panel.
Install safety key.
Check power line for proper voltage.
Inspect all connections to switch box and
motor for loose or open connections.
Inspect and replace switch if needed.
Replace capacitor.
Inspect and replace motor if needed.
Connect dust collector to dedicated circuit.
Inspect cord or plug for damaged insulation
and shorted wires.
Inspect all connections on motor for loose or
shorted terminals or worn insulation.
Install correct fuse or circuit breaker at power
source.
Reduce load on motor.
Clean motor fan with compressed air to
restore normal air circulation.
Reduce load on motor.
Inspect connections on motor for loose or
shorted terminals or worn insulation.
Correct low voltage conditions.
Install correct fuse or circuit breaker.
Inspect machine and tighten all fasteners.
Tighten fan or shim cover. Replace fan cover if
damaged.
Replace impeller.
Disengage stop button.
Replace batteries.
Follow instructions for clearing and resetting.