Angelo Po FX 61 G1/2 Manuel D'utilisation Et D'installation page 59

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

TABLE OF ALARM INDICATIONS
If the problem or fault noticed is not amongst those
listed in the table, consult the "Key to Alarms" table
provided below.
The information provided below s intended to identify
the alarm signals which appear on the display (7).
Important
Press button (12) to reset the alarm and the cook-
ing cycle restarts automatically; if this is not the
case, press the start key (16).
Alarm
Fault
No water in chamber, or water
H2O
pressure too low
No water at drain, or water pres-
H2O.
sure too low
No mains gas, gas pressure too
low or flame detection failure
GAS
Oven door opening or closure
OPE
request
English
12
16
Remedy
Check that mains water is
present or adjust the pressure
(see page 32); if the problem
persists inform the after-sales
service
Check that mains water is
present or adjust the pressure
(see page 32); if the problem
persists inform the after-sales
service
Press reset button (the button
may have to be pressed several
times); if the problem persists
inform the after-sales service
Open or close the oven door
Inform the after-sales service if
this message continues to be
displayed
- 21 -
7
Notes
Convection cooking cycles can
still be carried out
Convection and steam cooking
cycles can still be carried out
Stop cooking if this message is
repeated more than once
The cooking cycle does not start
until the door has been opened
or closed as required
Use and installation manual
IDM-39619500100.tif
IT
GB
DE
FR
ES

Publicité

Table des Matières
loading