Angelo Po FX 61 G1/2 Manuel D'utilisation Et D'installation page 47

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

6 – Humidity percentage setting key
- Sets the humidity percentage in mixed cooking mode (convection + steam).
Press the button once (the icon flashes) and set the percentage of humidity using
the knob (21). Wait about 5 seconds for the new value set to be saved.
- To modify the percentage of humidity during cooking: press once to display the
value of the humidity on the display (9).
Press the button and turn the knob (21) to modify the value set. Wait about 5 sec-
onds for the new value set to be saved.
In "convection cooking" mode you can adjust the percentage of opening of the
vent , which is shown on the display (9) ("0" = vent always open; "100" = vent
always closed).
- Accesses the "CIBUS PLUS 1" and "CIBUS PLUS 2" functions during a cooking
pause in "steam cooking" mode.
CIBUS PLUS 1: press the key (once) to set the "CIBUS PLUS 1" (92°C - 7 min.)
function, mode recommended for delicate and/or broad-leaf fresh (not frozen) veg-
etables.
CIBUS PLUS 2: press the key (twice) to set the "CIBUS PLUS 2" (95°C - 16 min.)
function, mode recommended for tough-fibre fresh (not frozen) vegetables.
Press once to return to the "CIBUS PLUS 1" mode.
7 – Temperature display
- Shows the value of the temperature set.
To display the real temperature inside the oven, keep button (4) pressed for about
6 seconds. The value on the display flashes at the start of a cooking process when
the temperature inside the oven is higher than the temperature set and/or during
automatic preheating when the set temperature has not been reached.
- During a pause in cooking, it shows the number of the "Regeneration" program
available for selection using button (18).
8 – Time and "product core probe" display
With button (5) (timer) pressed:
- In cooking pause status it shows the value of the time set.
- During cooking it shows the time left to the end of the cooking cycle.
With button (10) ("product core probe" temperature setting) pressed:
- In cooking pause status it shows the value of the temperature set.
- During cooking it shows the value of the temperature measured by the probe.
9 – Humidity percentage display
- In mixed cooking mode (convection + steam) it shows the value of the percentage
humidity set.
- Shows the function set in steam cooking mode (only if the CIBUS PLUS 1 or CI-
BUS PLUS 2 function has been set).
10 – "Product core probe" or "vacuum" temperature setting button
- For setting the cooking temperature inside the product measured by the core
probe (optional on level 1, standard on level 2) or with vacuum (optional): press
once (the icon flashes) to set the temperature using the knob (21).
- Modifies the temperature inside the product during cooking: press once to show
the temperature value on the display (8).
Press the button and turn the knob (21) to modify the value set.
11 – Burner icon: when lit, this indicates the burner is on.
12 – Reset button: resets the alarms (beepers and lights).
English
- 9 -
Use and installation manual
IT
GB
DE
FR
ES

Publicité

Table des Matières
loading

Table des Matières