5 .6
Connecting control voltage cables
• Mount the control panel at the helm position. There must be 150
mm of free space behind the panel.
• Connect the panel as shown in the dia-
gram.
See diagrams on page 165 if several pan-
els have to be connected.
• Connect the hub to a 12-Volt power sup-
ply.
n
ote
The hub should also be connected to
12 Volts in the case of a 48-Volt bow
thruster .
7
+
12 V
3
The CAN bus is a chain to which the bow thruster and the panels are
connected.
32
020806.03
Control panel
48 V
12 V
Control voltage fuse
M
+
12 V
3
n
ote
vetus® Installation instructions BOW PRO Series Thrusters: BOWA0651, BOWA0761 and BOWA0764
Terminator
Connection cable
Hub
+
M
7
At one end of the chain, the power supply (3) must be connected
and the terminator (7) must be connected at the other end!
- BPPJA
- BPPPA
Connection box thruster
Connection cable
CAN-bus supply
7
+
12 V
3
M