TECHNICAL DATA
MODEL
TYPE
OUTPUT
(1)
DELIVERY
(1)
FUEL
- net calorific value
- density
- viscosity at 20 °C
OPERATION
NOZZLES
STANDARD APPLICATIONS
AMBIENT TEMPERATURE
COMBUSTION AIR TEMPERATURE
ELECTRICAL SUPPLY
ELECTRIC MOTOR
MOTOR CAPACITOR
IGNITION TRANSFORMER
PUMP
delivery (at 12 bar)
fuel temperature
ELECTRICAL POWER CONSUMPTION
ELECTRICAL PROTECTION
IN CONFORMITY WITH EEC DIRECTIVES
(1) Reference conditions: Ambient temperature 20°C - Barometric pressure 1000 mbar - Altitude 100 m a.s.l.
• RADIO DISTURBANCE PROTECTION KIT
If the burner is installed in places particularly subject to radio disturbance (emission of signals exceeding 10 V/m) owing to the presence of an
INVERTER, or in applications where the length of the thermostat connections exceeds 20 metres, a protection kit is available as an interface
between the control box and the burner.
Code
TECHNICAL SPECIFICATIONS
PRESS
2nd stage
kW
Mcal/h
kg/h
1st stage
kW
Mcal/h
kg/h
kWh/kg
Mcal/kg
3
kg/dm
2
mm
/s max
number
°C
°C max
V
Hz
rpm
W
V
A
μF/V
V1 - V2
I1 - I2
kg/h
pressure range
bar
°C max
W max
10,2 (10.200 kcal/kg)
6 (1,5°E - 6 cSt)
- Intermittent (min. 1 stop in 24 hours)
- Two-stage (high and low flame) and single-stage (all - nothing)
Boilers: water, steam, diathermic oil
89/336 - 2004/108 - 73/23 - 2006/95 - 2006/42
3010386
11
GBW
605T50
178 - 356
153 - 306
15 - 30
107 - 178
92 - 153
9 - 15
Light oil
11,8
0,82 - 0,85
2
0 - 40
60
230 ~
+/- 10%
50
single-phase
2800
0,25
230
2,3
6,3/450
230V - 8kV
1,8A - 30mA
65
10 - 18
60
0,5
IP 40