Menu "Install Settings; Function H1 "Heat Or Cool - Sygonix tx.5 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

10. Menu "INSTALL SETTINGS"

• Briefl y push the "MENU" button (4) as described in chapter
8. b). The bottom-most display line shows "USER SETTINGS".
• Use the "–" (3) and "+" (2) buttons to switch between "USER
SETTINGS" and "INSTALL SETTINGS".
Select "INSTALL SETTINGS" and push the button „OK" (5).
• Then the buttons –" (3) and "+" (2) can be used to select the de-
sired function (see following subchapters or short description
in chapter 8. b).
• Confi rm the selection with "OK" (5).
• If you want to leave a function or the setting menu, push
the button „MENU" (4).
a) Function H1 "HEAT OR COOL"
The setting of this function divides on whether the room thermo-
stat is operated in connection with a heating or cooling device.
Depending on the selected operating mode ("HEAD", "COOL"),
the respective relay is switched at the terminal clamps socket
COM1/NC1/NO1 or COM2/NC2/NO2 when the measured tempera-
ture exceeds or undercuts the value in the programming (as of
which difference depending on the hysteresis setting).
• "HEAT" = Heating mode
The consumer is activated when the measured temperature is
below the value programmed.
Use this operating mode when the you want to control a heat-
ing.
• "COOL" = cooling mode
The consumer is activated when the measured temperature is
above the value programmed.
Use this operating mode when the you want to control a cool-
ing device/fan.
75

Publicité

Table des Matières
loading

Table des Matières