c) Manual Temperature Preselection for 1....24 Hours
Manual temperature preselection (see chapter 11. b) can apply for
a fi xed time of 1....24 hours. The present programming is not per-
formed during this time.
This function is available only if a programming is present
(see chapter 9. b).
This is not the case at initial commissioning (or after
restart). Therefore, manual temperature preselection
for a certain period of time cannot be made at this time
either.
1.
The room thermostat must be in the regular display (time/
temperature in the display).
Programming must be present at just described.
2. Set the desired manual temperature with the buttons "–" (3)
or „+" (2) (a hand icon appears).
The temperature can be selected within the set temperature
limits (see chapter 9. h).
3. Briefl y push the "MENU" button (4) once.
The display shows "LOCK HOUR" at the bottom and the hours
("1H"...."24H") fl ash to the right of it.
4. Set the desired time (1....24 hours) with the buttons "–" (3)
and "+" (2). Keep the respective button pressed for quick ad-
justment.
5. Confi rm the setting with "OK" (5).
The room thermostat then is back in regular display.
You can also prematurely terminate manual temperature prese-
lection by briefl y pushing the button "MENU" (4) or "OK" (5).
If manual temperature preselection was terminated, the hand
icon disappears. The temperature control is taken over by the set
programme again.