10. Menu "INSTALL SETTINGS"
• Briefl y push the "MENU" button (3) as described in chapter
8. b). The bottom-most display line shows "USER SETTINGS".
• Use the "–" (5) and "+" (6) buttons to switch between "USER
SETTINGS" and "INSTALL SETTINGS".
Select "INSTALL SETTINGS" and push the button "OK" (2).
• Then the buttons "–" (5) and "+" (6) can be used to select the
desired function (see following subchapters or short descrip-
tion in chapter 8. b).
• Confi rm the selection with "OK" (2).
• If you want to leave a function or the setting menu, push the
button „MENU" (3).
a) Function H1 "HEAT OR COOL"
The setting of this function divides on whether the room thermo-
stat is operated in connection with a heating or cooling device.
Depending on the selected operating mode ("HEAD", "COOL"),
the respective relay is switched at the terminal clamps socket
COM1/NC1/NO1 or COM2/NC2/NO2 when the measured tempera-
ture exceeds or undercuts the value in the programming (as of
which difference depending on the hysteresis setting).
• "HEAT" = Heating mode
The consumer is activated when the measured temperature is
below the value programmed.
Use this operating mode when the you want to control a heat-
ing.
• "COOL" = cooling mode
The consumer is activated when the measured temperature is
above the value programmed.
Use this operating mode when the you want to control a cool-
ing device/fan.
76
The home technology brand for the entire house. More information at www.sygonix.com