Flotec FP0F360AC Notice D'utilisation page 8

Masquer les pouces Voir aussi pour FP0F360AC:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Installation / Electrical
DISCHARGE PIPE SIZES
1. If increasing discharge pipe size, install reducer in
pump discharge port. Do not increase pipe size by
stages.
2. When pump is set away from the points of water use,
discharge pipe size should be increased to reduce
pressure losses caused by friction.
• Up to 100 ft (30M) run: Same size as pump dis-
charge port.
• 100 ft. to 300 ft (30-91M) run: Increase one pipe
size.
• 300 ft. to 600 ft (91M-183M)run: Increase two
pipe sizes.
PRESSURE TANK INSTALLATION –
DEEP WELL
A pressure tank provides a reservoir of water under pres-
sure and maintains a cushion of air pressure to prevent
pipe hammering and possible damage to plumbing com-
ponents. When water is drawn off through house fixtures,
pressure in tank is lowered and pressure switch starts
pump.
STANDARD TANK CONNECTION (Figure 7)
With a standard tank - an air volume control (AVC) adds
air to the tank when needed.To connect AVC to pump,
thread a 1/8" com pression fitting into tapped hole on
front of pump. Cut tubing to length to reach AVC; assem-
ble to fitting on pump and to AVC on tank. See installa-
tion instructions provided with tank and AVC for details.
Standard Tank
Air Volume
Control
(AVC)
1" Discharge
Relief Valve
AVC Tubing
Well Seal
Figure 7 – Pump on standard tank - shallow well
For parts or assistance, call Flotec Customer Service at
PRECHARGED TANK CONNECTION
(Figure 8)
No AVC is necessary with a precharged tank. A pre-
charged tank contains a factory provided air charge.
IMPORTANT: Pump pressure switch is set for a 40-60
PSI (275-414kPa) range and requires a tank pre-charge
of 38 PSI (262 kPa) for proper operation. See tank own-
er's manual for air charge. An annual check on tank air
charge is recommended.
1" Discharge
Figure 8 – Pump with pre-charged tank
WARNING
Pressure
Hazardous voltage. Can
Regulator
shock, burn, or cause
death.
Ground pump before
connecting to power
supply
AVC
age can cause fire or seriously damage motor and voids
Port
warranty. If in doubt consult a licensed electrician.
Use wire size specified in Wiring Chart. If possible,
connect pump to a separate branch circuit with no
other appliances on it.
2355b 0697
1-800-365-6832
Pre-Charged
Pressure Tank
6 0
4 0
2 0
8 0
1 0 0
Relief Valve
ELECTRICAL
Ground motor before
connecting to electrical
power supply.
Failure to ground motor
can cause severe or fatal
electrical shock hazard.
Do not ground to a gas
supply line.
To avoid dangerous or
fatal electrical shock,
turn OFF power to motor
before working on electrical
connec tions.
Supply voltage must be
within ±10% of name-
plate voltage. Incorrect volt-
8
Pressure
Regulator
2358b 0415

Publicité

Table des Matières
loading

Table des Matières