Télécharger Imprimer la page

3M ESPE Elipar S10 Mode D'emploi page 129

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 23
Guidance and manufacturer´s declaration – electromagnetic immunity
The Elipar S10 Dental Light Unit is intended for use in the electromagnetic environment specified below.
The customeror the user of the Elipar S10 Dental Light Unit should assure that it is used in such an environment.
IEC 60601
Immunity test
test level
Conducted RF
3 Vrms
IEC 61000-4-6
150 kHz to 80 MHz
Conducted RF
3 V/m
IEC 61000-4-3
80 MHz to 2,5 GHz
NOTE 1 At 80 MHz and 800 MHz, the higher frequency range applies.
NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption
and reflection from structures, objects and people.
Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land
a
mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically
with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic
site survey should be considered. If the measured field strength in the location in which the Elipar S10 Dental
Light Unit is used exceeds the applicable RF compliance level above, the Elipar S10 Dental Light Unit should
be observed to verify normal operation. If abnormal performance is observed, additional measures may be
necessary, such as re-orienting or relocating the Elipar S10 Dental Light Unit.
Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 10 V/m.
b
Compliance level
10 V
3 V/m
Electromagnetic environment -
guidance
Portable and mobile RF communications
equipment should be used no closer to
any part of the Elipar S10 Dental Light
Unit, including cables, than the recom-
mended separation distance calculated
from the equation applicable to the
frequency of the transmitter.
Recommended separation distance
3,5
– – –
d = [–––]√
P
V
1
3,5
– – –
d = [–––]√
P 80 MHz to 800 MHz
E
1
7
– – –
d = [–––]√
P 800 MHz to 2,5 GHz
E
1
where p is the maximum output power
rating of the transmitter in watts (W) ac-
cording to the transmitter manufacturer
and d is the recommended separation
distance in metres (m).
b
Field strengths from fixed RF trans mit-
ters, as determined by an electromag-
netic site survey,
should be less than
a
the compliance level in each frequency
range.
b
Interference may occur in the vicinity of
equipment marked with the following
symbol:
127

Publicité

loading