Télécharger Imprimer la page

RIB K500 Manuel D'utilisation page 25

Masquer les pouces Voir aussi pour K500:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

SYSTEM LAY-OUT
1 - K500 operating device
2 - External photocells
3 - Rack of Module 4
4 - Key selector
5 - Radio antenna
6 - Blinker
7 - Limit switch plate (cams)
8 - TOUCH Safety edge or VERTIGO photocell
9 - TOUCH Safety edge or VERTIGO photocell
10 - Internal Photocells
11 - Photocell columns
12 - Mechanical stops
TECHNICAL FEATURES
Irreversible operating devices for sliding gates with a maximum weight of 500 kg /
4900 lbs.
The irreversibility of this operating device allows you to avoid using any electric lock for
an effective closing of the gate. The motor is protected by an heat probe, that temporary
interrupts the operating cycle in case of prolonged use.
274
Measurements in mm
TECHNICAL DATA
Max. leaf weight
Rack
EEC Power supply
Thrust force with constant turns
Max torque
Motor capacity
Power absorbed
Capacitor
Power supply 120V
Thrust force with constant turns
Max torque
Motor capacity
Power absorbed
Capacitor
Normative cycles 230V/50Hz
Normative cycles 220V/60 Hz
Normative cycles 120V/60 Hz
Daily operations suggested
Service
Guaranteed consecutive cycles
Grease
Weight of electroreducer
Noise
245
Working temperature
Protection
25
K500
kg
500
4
230V~ 50Hz
230V~ 60 Hz
N
400
Nm
9,5
W
229
A
1,21
µF
10
120V~ 60 Hz
N
500
Nm
12
W
259
A
3,5
µF
35
12 - 30s/2s
10 - 30s/2s
9 - 30s/2s
300
60%
25/5m
BECHEM HIGH-LUB GF550
kg
8
db
<70
°C
-10 ÷ +55
IP
54
G
B
1
228
1,05

Publicité

loading