10.3 Critical Bolt Connections - Atlas Copco HiLight E2 Manuel D'instructions

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 75

10.3 Critical bolt connections

Parts to assembly
Mast - Base frame
Mast clamp - Structure
Mast break (stoppers)
Internal fixing rope
External fixing rope
Winch - Mast
Friction plates
Light support - Mast tube (Transport position)
Light support - Mast tube (Operating position)
Floodlight support - Light support
Floodlight - Floodlight support (Transport position))
Floodlight - Floodlight support (Operating position)
Wheel - Axle
Axle support - Frame
Handles - Canopy
Note: All the values mentioned above are applicable for dry or lightly oiled bolts.
Dimension
Quality
M12
8.8
AC - STD 4369 K
M8
8.8
AC - STD 4369 K
M8
8.8
M10
8.8
M10
8.8
M10
8.8
M5
8.8
M8
8.8
M8
8.8
M10
8.8
M10
8.8
M10
8.8
M16
8.8
M8
8.8
M8
8.8
- 38 -
Applicable
Torque
standard
(Nm)
73
20
AC - STD 4369
20
AC - STD 4370
41
AC - STD 4371
41
AC - STD 4369
41
AC - STD 4369
5
AC - STD 4369
20
AC - STD 4369
20
Tested
25
Tested
20
Tested
20
Tested
120
AC - STD 4369
20
AC - STD 4369
20
Allowed
Additional
deviation
treatment
(Nm)
± 18
± 5
± 5
± 10
± 10
± 10
± 1.2
± 5
± 5
± 5
± 1.2
0
± 30
± 5
± 5

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Hilight e3+Hilight esf

Table des Matières