Active:
Relay is activated when the
preset value is reached.
Passive:
Relay is de-energized when the
preset value is reached.
7.9
Setting the preset
7.9.1 Setting via Decade Keys
In the operating mode, the preset value will always
be displayed in the lower line. This is except for the
output operations AddBat, SubBat and AddTot.
Press the Prog/Mode key until
the preset to be changed is
displayed -
Press any decade key
Display switches to the editor mode
Set the desired preset value
using the decade keys
Approx. 3 s after the last press of
the decade keys or by pressing
the Reset key the new preset
value will be accepted and the
counter will switch back to
operating mode.
7.9.2 Setting with Teach-In Function
Program the MPI input to tEAch
In programming mode, select the
preset to be changed using the
Prog/Mode key
Briefly activate the MPI (NPN or PNP input logic)
The current count value will be adopted as
the new preset value
The preset value can subsequently be
further modified via the decade keypad.
7.10
Set Function
Both the pulse counter and the timer can be set to
a default value by means of the Set function.
www.kuebler.com
Program the MPI input to SEt
Set menu item SEtPt to the
desired value
Briefly activate the MPI (NPN or PNP input logic)
For add. output operations the pulse
counter or timer will be set to the SEtPt
default value
For sub. output operations the pulse
counter or timer will be set to the amount
of the value of Preset 2 and the value of
SEtPt .
8
Error message
Err 1
Set value is outside the permitted range
9
Connections
9.1
Signal and Control Inputs
N° Designation
1
AC: 24 VDC/80 mA
DC: U
connected
B
through
2
GND (0 VDC)
3
INP A
4
INP B
5
RESET
6
LOCK
7
GATE
8
MPI
Function
Sensor supply
voltage
Common connection
Signal and Control
inputs
Signal input A
Signal input B
Reset input
Keypad lock
Gate input
User input
Page 15