5.1. Prior check
- Check that the equipment is free from damage.
- Check that the details on the packing slip correspond to the details of the product received.
If you have any problems and/or doubts, please contact Simco-Ion Netherlands or the agent in
your region.
5.2. Fitting the anti-static bar
Note:
- Conductive machine parts in the vicinity of the anti-static bar have a negative
influence on its operation.
- For optimum results, the anti-static bar must be fitted as per Figure 3.
- Fit the anti-static bar:
Directly in front of the place where static electricity causes problems.
At an optimum distance from the material to be neutralised:
o 50 – 500 mm (Performax Easy Speed)
o 100 – 500 mm (Performax Easy)
With the emitters facing in the direction of the material to be neutralised.
"R" = operating
distance + 40 mm
Figure 3: Optimum position of the Performax Easy and Performax Easy Speed
Performax Easy/Performax Easy Speed_UM_9752152130_NL_D_GB_F_V3_4