Simco-Ion Performax Easy Notice D'utilisation page 45

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

9. Faults
Warning:
- Disconnect the power supply before carrying out work on the unit.
Table 1: Faults
Signalling
LED on anti-static bar
does not light up
LED on the anti-static
bar flashes green
LED on anti-static bar
lights up red
LED on anti-static bar
lights up green
LED on the anti-static
bar flashes red
Performax Easy/Performax Easy Speed_UM_9752152130_NL_D_GB_F_V3_4
Problem
No high voltage at
emitters
No high voltage at
emitters
Anti-static bar
overloaded
No/poor ionisation,
despite high voltage
at the emitters
High voltage at the
emitters, no HV OK
signal
Cause
No supply voltage
Wiring fault
No remote on/off signal
Wiring fault
Anti-static bar fouled
Anti-static bar fitted
too close to conductive
machine parts
Anti-static bar fouled
Emitters are damaged
Anti-static bar incorrectly
positioned
Emitters are covered
HV OK overloaded
Wiring fault
Solution
Switch on supply
voltage
Locate fault and
remedy, see 5.3
Connect/activate
remote on/off
Locate fault and
remedy, see 5.3
Clean anti-static bar
Move anti-static bar
Clean anti-static bar
Replace the anti-static
bar
Reposition the anti-
static bar, see 5.2
Remove the cover
Load HV OK differently
Locate fault and
remedy, see 5.3
44

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Performax easy speed

Table des Matières