Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

(—with signalling —)
Figure 2: Performax Easy Speed dimensions and optional connectors

5. Installation

Warning:
- Electrical installation and repairs must be carried out by a skilled electrical engineer
according to the applicable national and local regulations.
- The equipment must be properly earthed. Earthing is required to ensure safe and
proper operation and to prevent electrical shocks upon contact.
- Disconnect the power supply before carrying out work on the unit.
- The anti-static bar must only be powered by a Limited Power Source (LPS) or
NEC Class 2 power supply. An LPS certified power supply has a limited output power,
which means that it always generates a safe output voltage.
The 0 V of the power output must be earthed correctly (see section 5.2.3.).
The anti-static bar can be powered by a 24 V DC power supply already available on the
machine (if it meets the above requirements), but also by a Desktop power unit from Simco-Ion
Netherlands.
The power units recommended by Simco-Ion Netherlands:
Part number
Description
4524001000
Desktop, 100–240 V AC to 24 V DC for 1 anti-static bar (IP40).
7519020435
DIN rail power supply, 100–240 V AC to 24 V DC for a maximum of
20 anti-static bars (IP20).
7519020425
DIN rail power supply, 100–240 V AC to 24 V DC for a maximum of
4 anti-static bars (IP20).
7519020430
DIN rail power supply, 100–240 V AC to 24 V DC, (UL listed)
4 anti-static bars (IP20).
Performax Easy/Performax Easy Speed_UM_9752152130_NL_D_GB_F_V3_4
(—————————without signalling ——————)
*
*
*
screw
connection
GB
37

Publicité