Installation Instructions
4. Assemble LuminIce™ to bracket with three screws
provided. The bulb and bulb wiring must face toward
the rear of the ice machine to allow bulb
replacement with LuminIce™ in place.
Attach With Three Screws
5. Mount transformer on evaporator bulkhead above
control box. Attach supplied wire clip and route line
voltage wires through clip.
Install Transformer
Route Line Voltage Wires Through Clip
6
Attach Wire Clip
6. Route line voltage wires (Black & White) through line
voltage Heyco fitting and attach to L1 and L2
contactor terminals.
Route Through Line Voltage Heyco
Attach to Contactor Terminals
NOTE: QuietQube models do not have open terminals
on contactor. Remove two wires from contactor, install
supplied electrical connector and connect wires.
Wires Removed From Contactor
LuminIce Power
Section 2
and
Contactor
Part Number 000008463 10/11
L2
L1