Section 2
7. Route line voltage wires (Black & White) through line
voltage Heyco fitting. Disconnect LI & N wires and
install L1 & N of wiring adapter to the incoming
power supply wires. Connect removed wires and
LuminIce™ wires to adapter.
Incoming Power Supply
L1
N
8. Remove four screws to allow access for low voltage
wire routing.
Part Number 000008463 10/11
Ice Machine Power
LuminIce Power
Remove four screws
9. Route low voltage wiring (black and yellow wires) to
the LuminIce™, and snap wire harness connectors
together. Reinstall screws removed in previous step.
10. Install LuminIce™ hoses:
•
Route bottom port LuminIce™ hose to rear
evaporator bulkhead hole.
•
Route top port LuminIce™ hose to forward
evaporator bulkhead hole.
Installation Instructions
11