ENGLISH
Thank you for buying this product, our company is sure that you will be more
than satisfied with its performance.This product is supplied with a "Warnings"
leaflet and an "Instruction Manual". These should both be read carefully as
they provide important information about safety, installation, operation and
maintenance. This product complies with recognised technical standards
and safety regulations. We declare that it is in conformity with the following
European Directives: 89/336/EEC, 73/23/EEC, 98/37/EEC (and subsequent
amendments).
1) GENERAL SAFETY
WARNING! An incorrect installation or improper use of the product can
cause damage to persons, animals or things.
The Company declines all responsibility for any consequences resulting from
improper use of the product, or use which is different from that expected and
specified in the present documentation.
The "Warnings" leaflet and "Instruction booklet" supplied with this product
should be read carefully as they provide important information about
safety, installation, use and maintenance.
Scrap packing materials (plastic, cardboard, polystyrene etc) according
to the provisions set out by current standards. Keep nylon or polystyrene
bags out of children's reach.
Keep these installation instructions together with the technical brochure
for future reference.
This product was exclusively designed and manufactured for the use
specified in the present documentation. Any other use not specified in
this documentation could damage the product and be dangerous. The
Company declines all responsibility for any consequences resulting from
improper use of the product, or use which is different from that expected
and specified in the present documentation.
Do not install the product in potentially explosive atmosphere or wherever
there is a fire risk.
The construction components of this product must comply with the following
European Directives: 89/336/CEE, 73/23/EEC, 98/37 EEC and subse-
quent amendments. As for all non-EEC countries, the above-mentioned
standards as well as the current national standards should be respected
in order to achieve a good safety level.
The Company declines all responsibility for any consequences resulting
from failure to observe Good Technical Practice when installing the device
described in the present manual.
The installation must comply with the provisions set out by the following
European Directives:89/336/CEE, 73/23/EEC, 98/37 EEC and subsequent
amendments.
Disconnect the electrical supply before carrying out any work on the
installation. Also disconnect any buffer batteries, if fitted.
Fit an omnipolar or magnetothermal switch on the mains power supply,
having a contact opening distance equal to or greater than 3,5 mm. Also
fit an adequate cut-out device for the buffer batteries.
Check that a differential switch with a 0.03A threshold is fitted just before
the power supply mains.
Check that earthing is carried out correctly: connect all metal parts of the
closing mechanism and all system components provided with an earth
terminal.
Fit all the safety devices (photocells, electric edges etc.) which are needed
to protect the area from any danger caused by squashing, conveying and
shearing.
Position at least one luminous signal indication device (blinker) where it
can be easily seen, and fix a Warning sign next to the structure.
The Company declines all responsibility with respect to the automation
safety and correct operation when other producers' components are
used.
Only use original parts for any maintenance or repair operation.
Do not modify the automation components, unless explicitly authorised
by the Company.
Instruct the product user about the control systems provided and the
manual opening operation in case of emergency.
Do not allow persons or children to remain within the automation opera-
tion area.
Keep radio control or other control devices out of children's reach, in
order to avoid unintentional automation activation.
The user must avoid any attempt to carry out work or repair on the automa-
tion system, and always request the assistance of qualified personnel.
Anything which is not expressly provided for in the present instructions,
is not allowed.
Installation must be carried out using the safety devices and controls
prescribed by the EN 12978 Standard.
2) GENERAL OUTLINE
Underground anti-waiting bollard, compact and sturdy.
It consists of a steel rod coated with reflecting material, and powered by
12 -
STOPPY - Ver. 05
INSTALLATION MANUAL
an oil-bath motor; all protected by a hot-galvanised steel cylinder which is
fitted underground.
The PERSEO control panel allows up to four bollards to be controlled si-
multaneously (Fig.8).
Besides the standard version, STOPPY is available in the following models:
"L" series provided with signal indication blinker lights and, on request, "R"
series provided with a heated resistor which also allows the bollard to be
used in particularly cold climates (as much as –25°C) and "A" series provided
with a magnetic sensor for connection to an antitheft system.
Accessories:
Electric brake buffer battery kit, which allows the bollard to be kept in the
access closed position even when the mains power is off.
3) TECHNICAL SPECIFICATIONS FOR STOPPY ACTUATOR
Motor: ..................................................................230Va.c. ±10% 50/60 Hz*
Capacitor: ............................................................................................. 8 µF
Absorption: ......................................................... 1.2 A (230V) 2.4 A (110V)
Work frequency:............................................................................ 2000/24h
Maximum torque:..................................................................700 N (~70 kg)
Degree of protection: ............................................................................ IP67
Control panel .................................................................................... Perseo
Electric brake:.................................................................................. 24Vd.c.
Working time:.........................................................................6s+slow-down
Working temperature ............................................................. –15°C + 60°C
Working temperature for "R" versions ................................... –25°C + 60°C
Front impact resistance on rod raised by 200 mm: ...................5,000 Joule
Static Load:........................ Max. sustainable weight with raised rod: 300kg
Dynamic Load:...................................Max. pushing force on closing: 100kg
Weight:........................................................................................... 90 kg ca.
Dimensions :.................................................................................. see fig. 1
Manual manoeuvre:............. When the current is off, it becomes reversible.
(* other voltages available on request)
4) TECHNICAL SPECIFICATIONS FOR PERSEO CONTROL PANEL
Power supply: ......................................................230Va.c. ±10% 50/60Hz*
Absorbed current: .................................................6A max (with 4 bollards)
Maximum no. of motors: ......................... up to 4 STOPPY bollards (Fig.8)
Dimensions: ..............................................................................see figure 4
Fuses: ...................................................... F2: T2A / F3: T2A / F4: T315 mA
(* other voltages available on request)
WARNING! The 100V 50 and 60Hz control units can control two anti-
transiting bollards in parallel only, instead of four.
5) PRELIMINARY CHECKS
Check that the installation base is stable and level.
For correct operation, the bollard does not require precise verticality;however,
to obtain a good aesthetic result, it is advisable to proceed to levelling the
installation area so as to ensure that the rod stroke is perfectly vertical.
6) FOUNDATION DIGGING AND BOLLARD POSITIONING
Proceed to digging a hole in the ground to fit the bollard in.The hole must
have a depth of about 110 cm and a diameter of about 50/60 cm.
Lay a 20-cm thick gravel foundation for drainage, as shown in fig. 2. Then
lay a 5-cm thick fine sand layer to complete the foundation base for the
bollard.
Position the bollard, paying attention to the foundation level (the ring nut
must be placed at the same level as the transit surface) and base level-
ling.
Carry out electrical installation (see paragraph 7).
Fill the hole up to a level of about 25 cm with compact sand.
At this point, suitably position the sheath and carry out the necessary wiring
installation, then lay out a concrete casting, which will be later covered by
asphalt or other flooring material to reach the transit surface level.
7) ELECTRICAL INSTALLATION SET-UP
Lay out the electrical installation as shown in fig. 3, making reference to the
current CEI 64-8, IEC 364 (HD 384 harmonised) electrical standards, and
other national standards.
WARNING! For connection of the control panel to the mains, use a
multicolour cable having a minimum 3x1.5 sq mm cross section of
the type set out by the current standards. For example, if the cable is
installed outside (in the open air), it must be at least equal to H07RN-F,
whereas, if it is installed inside (in a raceway), it must be at least equal
to H05 VV-F and have a 3x1.5 sq mm cross section.
To connect the bollard to the control panel, use cable supplied as standard
(50% breakagepossibility)
Max. sustainable weight with lowered rod: 15,000 kg