2. SAFETY
The present manual contains vital instructions, which must be follo-
wed during installation and commissioning. This is why it must be
carefully read by the fitter and the user, before installation and com-
missioning. Not only the general instructions in this section, but also
the specific recommendations made in the paragraphs below, must
be observed.
2.1 Symbols accompanying the manual's instructions
Call attention to a potential risk that might affect the safety of
the persons.
Call attention to a potential electrical risk that might affect
the safety of the persons.
Indicates an instruction whgose non-observation
ATTENTION !
may lead to a damage of the material and its
running.
2.2 Qualification of staff
Make sure that the staff installing the pump are adequately qualified.
2.3 Dangers run if the instructions are not followed
Not obeying the safety instructions may endanger both staff and the
system. It may also invalidate the guarantee.
More specifically, the dangers run may be the following :
- Failure of some of the system's main functions.
- Danger for staff in the event of electrical or mechanical malfunc-
tions in the machine.
2.4 Safety instructions for the user
The instructions must be obeyed to exclude any risk of accidents.
Any electrical risks must also be eliminated.
Respecter les normes électriques en vigueur.
2.5 Safety recommendations for inspection and installation works
The user must ensure that the works are performed by a qualified spe-
cialist who has read the present manual.
The pump must only be worked on when it is switched off.
2.6 Modification of the machine and use of unapproved spare parts
The system may only be modified subject to Salmson's prior authori-
sation. Using original spare parts and accessories authorised by the
manufacturer guarantees safety.
Using other parts releases Salmson from any liability.
2.7 Unauthorised use
The safe operating of the system delivered may only be guaranteed
if the recommendations given in section 1 of the manual are follo-
wed. The values indicated in the data sheet should not be exceeded
under any circumstances.
The device has not been designed for continuous operation!
The maximum flow rate stated applies to intermittent opera-
tion (S3 - 15%). The maximally possible inlet quantity always
must be smaller than the delivery of one pump in the respective ope-
rating point.
Using the lifting station outside the recommended conditions may
cause an excess load that the system is not designed to withstand.
Not obeying this warning may endanger staff and the machine.
3. TRANSPORT AND STORAGE
The system is delivered on a pallet. The pallet must
ATTENTION !
be transported using appropriate lifting systems.
Static stability must also be ensured.
The system must be protected against mechanical damage.
4. PRODUCTS AND ACCESSORIES
The SANITSON PREMIUM lifting station is a system with one or two
pumps, which may be used in two types of system :
- As an indoor system for the suction of valve water,
- As an outdoor pumping station with a buried tank.
4.1 Description
This station is fitted with a polyethylene tank with an accessible cover,
and in particular including a stainless piping, a non-return valve and
a stop valve. The pump, the level detection device and the control
box, must be ordered separately (Table 2).
4.2 Supplies
4.2.1 "Professional" model
- The SANITSON PREMIUM; a station fitted with a tank , and in parti-
cular including a stainless piping, a flange of fixing with integrated
non-return valve, a stop valve.
- 1 tank cover with gasket.
- 1 crown saw Ø 124 mm.
- 1 seal for the connection of the pump on piping.
- 1 ND 100 suction inlet seal (for Ø 110 mm pipe).
- 1 section of Ø 50 mm transparent hose with clamping collars to
connect the diaphragm hand pump.
- Screws and bolts.
- Installation and commissioning manual.
- Tank fastenings.
4.3 Accessories
Accessories must be ordered separately.
- Seal for ND100 inlet piping (for Ø 110 mm pipes with crown saw).
- Stop valve for the ND100 inlet piping.
- ND100 joint flange with hose and clamping flanges to connect
the stop valve inside the inlet pipe.
- 1"1/2 hand pump (without pipes).
- Float switch for alarm control.
- Clamping coupling to connect the station to the stainless dischar-
ge duct :
G 1"1/2 - Ø ext 50 mm
G 2" - Ø ext 63 mm
G 2"1/2 - Ø ext 75 mm
- 300 mm extension with gasket.
- Suction cup (priming)
Detailed list and description: see catalogue/technical manual.
15
G 1"1/2 - Ø ext 63 mm
G 2" - Ø ext 75 mm