5.4 Mounting the pump
- Disconnect the piping (item 1) flange of fixing (item 2) and to leave
it the tank.
- After having positioned the flat joint of sealing, fix the pump on the
square flange of piping using provided screws.
Characteristic of assembly for pumps SVO205 :
- The gasket DN50 is not provided because the function is provided
by the mask attaches integrated into the pump housing.
- In order to guarantee a sufficient length of screw in catch in the
pump housing, not to put a gasket under the head of screw.
- Reposition the unit pumps + piping on the support of fixing (item 2).
- For electrical connection, refer to sections 5.3 and 5.7.
5.5 Mounting the cover
- Before screwing on the cover, push the gasket up to the rim.
The gasket should not slide into the screw threads
ATTENTION !
during tightening !
- If the system is being installed indoors, the cover must be screwed
on as tightly as possible to ensure tightness in the event of damage
and prevent any infiltration of water or gas.
- To prevent any unauthorised opening of the cover (child safety),
particularly for buried installation, the cover may be locked in place
using the screw provided. To this end, drill a Ø 3mm hole in the
recession predefined on the tank's cover and flange (10° angle),
then screw in the screw.
(See FIG. 11 - below).
FIG. 11
5.6 Mounting the extension
- If necessary, a 300mm extension may be fitted. To screw it on using
the gasket, refer to the section on mounting the cover.
- After screwing on the extension, you should prevent it from loose-
ning by using the screws provided. To this end, drill a Ø 3mm hole in
the lower threading zone of the extension and tank threading, then
screw in the screws (See FIG. 12 below).
A single extension may be fitted.
ATTENTION !
If several extensions are fitted and the build-in
depth becomes therefore greater than 1.3 m, the system's static
safety is no longer guaranteed and the pump(s) may no longer be
accessed !
2
1
FIG. 10
Flange piping of
discharge integrated.
17
5.7 Positioning the level detection system IPAE 0-1 mCE (4-20mA)
- Secure the APS inside Ø 32 PVC pipe in support at the bottom of the
tank.
- In the control unit, set the APS trip levels. The minimum setting values
may be the following (for an APS positioned at the bottom of the
tank and the pipe of arrival of the waste positioned like above -
FIG. 13) :
Pump n°1 trip height
Pump n°1 shut down height
Overflow alarm height
Pump n°1 trip height
Pump n°1 shut down height
Pump n°2 trip height
Pump n°2 shut down height
Overflow alarm height
- Also see setting control unit YN3000.
Make sure that the values of settings allow a use
ATTENTION !
in full safety of the installation.
The pump's shut down level should not exceed the motor frame's
lower limit (Rep. M). The pump start-up level must be set level with
the bottom of the inlet pipe to guarantee the cooling of the pump
motors (Rep. H).
Not obeying these values may cause damage to the pump.
5.8 Electrical connection
Electrical connection must be performed by an approved
electrician, in accordance with the current local recommen-
dations.
- The type of current and the supply voltage must be in line with the
indications given on the nameplate.
- Protection via fuse on the supply side and an FI circuit breaker must
be provided in accordance with the current recommendations.
- The pump or the system must be earthed in accordance with the
recommendations.
FIG. 12
FIG. 13
Module with 1 pump
39 cm
20 cm
41 cm
Module with 2 pumps
38 cm
20 cm
40 cm
22 cm
41 cm