SOFTWARE

It is necessary to read software inside the new control
unit by means of a SD card, if the control unit has
been exchanged.
The software is placed on a SD card which must
contain the folders and one or more of the files as
shown below. The folder names must be saved in BIG
letters and with the original names.
Software reading
• Insert the SD-card in the slide in the right side of
the machine.
• Turn on the machine.
• The display flashes shortly with three lines.
• Wait until the set current is displayed.
• Turn off the machine and remove the SD card.
• The machine is now ready for use.
All machine user settings are deleted when
new software has been inserted. Therefore,
always remove the SD-card from the machine
after the software update. Thereby, continuous
software update is avoid each time the machine
is turned on.

TECHNICAL DATA

Power source:
Mains voltage (50Hz-60Hz)
Fuse
Mains current, effective
Mains current, max.
Power, (100%)
Power, max
Open circuit power
Efficiency
Efficiency factor
Current range
Duty cycle 100 % at 20°C
Duty cycle
60% at 20°C
Duty cycle 100% at 40°C
Duty cycle
60% at 40°C
Duty cycle
max. at 40°C
Open circuit voltage
1
Sphere of application
2
Protection class
Norm
Dimensions (hxwxl) cm
Weight
S
1
This machine meets the demand made for machines which are to
operate in areas with increased hazard of electric chocks
2
Equipment marked IP23 is designed for indoor and outdoor applications
18
AUTOMIG 273i
3x400 V ±15%
10 A
7.6 A
13.2 A
5.3 kVA
9.1 kVA
20 W
0.88
0.93
10-270 A
230 A
245 A
175 A
195 A
25 %
52 V
S
IP 23
EN/IEC60974-1
EN/IEC60974-5
EN/IEC60974-10 (Class A)
55x25x64
26 kg