Télécharger Imprimer la page

MCS Master 310S Mode D'emploi page 49

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 43
AL
► the combustion chamber and heat ex-
BG
changer are sufficiently cooled and do not
overheat.
CN
WARNING! Only hoses that are
CZ
suitable for continuous operation of
DE
at least 150
C (temporary allowable
o
temperature:180
DK
of first 2 meters, and at least 85
on the rest of the hose length should
EE
be attached to the heater. It is re-
commended to use MASTER brand
ES
hoses.
FI
WARNING! It is possible to attach
FR
a special perforated hose made of
PE foil, however first use a special
en
kit dedicated to each heater model
(fig. 3) You can purchase such kits
GR
at your nearest MASTER brand ven-
HR
dor.
HU
WARNING! After connecting the
distributing hose, pay attention to
IT
its placement. In order to limit the
LT
air flow obstruction and device load,
we recommend to lay the hose so as
LV
to limit the number of bends to the
minimum. Moreover, do not bend the
NL
hose at angles less than 90°. Addi-
tionally, the initial 2 meters of the
NO
duct should not be bent (fig. 4).
PL
CONNECTION TO FLUE (fig. 5, 6, 7)
PT
Thermal efficiency and proper functioning are
directly related to correct draft in the chimney.
RO
► Make sure distance between heater and
chimney is as short as possible, do not create
RU
closed angles or chimney section reductions.
► If the heater is not connected to an outside
SE
chimney, it must be equipped with a vertical
SI
steel fl ue and a draft regulator.
SK
►►4. RUNNING THE HEATER
TO START THE HEATER
TR
► Set switch (2) on position "O", connect
heater to mains (see model plate for electri-
UA
cal specifi cations).
► If the heater is to be run under manual
YU
C) on the section
o
control, set switch (2) on position
ner will start and after a short time of com-
bustion chamber preheating the main venti-
lator will start.
► If the heater is to be run under automatic
control, set desired value on selected con-
trol, set switch (2) on position
will now start and stop automatically.
C
o
► If after these operations the heater does
not run properly, revert to chapter "OBSER-
VED FAULTS, POSSIBLE CAUSE REME-
DIES" and find out reason of malfunction.
TO STOP HEATER
► In manual mode, set switch (2) on position
"O" or turn off control in automatic mode.
► Burner will stop and main ventilator will
stop later when combustion chamber has
cooled off.
WARNING! Never pull plug to stop
heater. Never pull plug before heater
has stopped by itself.
VENTILATION
To run your heater as a ventilator only, set
switch (2) on position
►►5. MAINTENANCE
Troublefree running of your heater requires
regular maintenance. Unplug heater before
doing any maintenance work.
CLEANING OF COMBUSTLON CHAMBER
AND EXCHANGER
This operation must take place at least once
a year when the heating season is over. Ex-
cessive sooting is mainly due to incorrect fl
ue, incorrect burner setting or bad quality
fuel. Excessive sooting can be diagnosed if
heater has rough starts. Access to exchan-
ger is made via two access doors (one via
air outlet, the other after removal of the body
panel opposite to
combustion chamber require removal of bur-
ner. Soot and debris can be removed with a
vaccum cleaner.
CLEANING OF VENTILATOR
Clean ventilator with compressed air after re-
moval of aspiration grilles.
the bur-
the heater
.
the burner). Access to

Publicité

loading

Ce manuel est également adapté pour:

470s690s690t