was safe and compliant with the regulations
and standards in that particular country.
WARNING! Device installation
should be consulted with the facility
builder and the chimney cleaner. Re-
gardless of the method of installa-
tion, it is required to ensure proper
ventilation in the device room.
► Check heater before starting and regularly
during operation.
► Keep children and animal away from he-
ater.
► Always separate heater from mains when
not in use.
► Never fi t heater with a different burner or
increase burner output over nominal power
of heater as indicated on specifi cation adhe-
sive.
► Never block air inlet or outlet since this
could lead to ventilation motor overload and
consequently to overheating of unit.
WARNING! Only the burners
which are chosen and supplied by
the manufacturer can be used. If
another type of burner is used the
heater no longer complies with CE
regulations.
There are three safety devices which are ac-
tivated in case of serious malfunction. The
Burner Control Device, which is mounted
on the burner and has a restart button, auto-
matically stops the burner if the fl ame goes
out. The Overheat Thermostat, TS, of the
manuel restart type, is activated if the tem-
perature of the combustion chamber rises
above the set maximum limit; the warning
light (8) lights up and the heater stops wor-
king. The Thermal Relay, RT, is activated if
the fan motor starts to use more electrical
current than the maximum permitted limit;
the warning light (9) lights up and the heater
stops working. If any of these safety devi-
ces are activated you should check carefully
what the problem actually is before pressing
the restart button and starting the heater off
again (cfr. OBSERVED FAULTS, CAUSES
AND REMEDIES). Overheat safety thermo-
stat, TSS, shuts down the heater if air fl ow is
not suffi cient to cool off combustion cham-
ber: the heater will restart automatically as
soon as the heater has cooled down enough.
►►3. INSTALLATION
WARNING! The following opera-
tions must be carried out by quali-
fied personnel only.
ELECTRICAL CONNECTIONS AND SET-
TINGS.
WARNING! The mains supply to
the heater must be earthed and have
a magneto-thermal switch with dif-
ferential. The power cord must be
connected to a switch board which
has a disconnecting switch.
The following operations must now be car-
ried out:
► Plug in the power cord having read the ad-
hesive label which details electricity supply
characteristics.
► Connect accessories such as the room
thermostat or clock to
switchboard: electric wire must be connec-
ted by means of the cable fastener (7) to the
terminals. Having completed all these opera-
tions check carefully that all electrical con-
nections correspond to the wiring diagram
and check the setting of thermostat TV (cf.
Technical Specifi cations). When the heater
is fi rst turned on you must check that the
fan does not use more current than the maxi-
mum permitted limit. Finally, to regulate the
burner follow the instructions in the Burner
Instruction Manual.
CONNECTION
TO
As a standard, the heater is supplied with a
1-way air exhaust panel. Heaters equipped
with such panel require additional hoses to
distribute the hot air. After connecting the
distributing hose for hot air please check if:
► the ventilator engine does not draw more
power than the allowable maximum value,
the unit's electric
HOT
AIR
DUCTS
AL
BG
CN
CZ
DE
DK
EE
ES
FI
FR
en
GR
HR
HU
IT
LT
LV
NL
NO
PL
PT
RO
RU
SE
SI
SK
TR
UA