For your safety
Strictly follow the Instructions for Use
Any use of the device requires full understanding and strict observation of these
Instructions for Use. The device is to be used for the purposes specified here
only.
Maintenance
The maintenance intervals and measures specified in the Technical Handbook
as well as the specifications in the Instructions for Use/data sheets of the
® 2)
sensors DrägerSensor
used must be carefully observed.
Device maintenance must only be carried out by trained service personnel.
Accessories
Only the accessories specified in the order list in the Technical Handbook
be used.
Safe coupling with electrical devices
Devices that are not mentioned in these Instructions for Use or in the Technical
1)
Handbook
can only be coupled electronically after consultation with the
manufacturers or an expert.
Use in areas subject to explosion hazards
Devices or components for use in explosion-hazard areas, which have been
tested and approved according to national, European or international Explosion
Protection Regulations, may only be used under the conditions explicitly
specified in the approval and with consideration of the relevant legal regulations.
The equipment or components may not be modified in any manner. The use of
faulty or incomplete parts is forbidden. The appropriate regulations must be
observed at all times when carrying out repairs on these devices or components.
Repairs to the device may only be carried out by trained service personnel in
accordance with the maintenance instructions of Dräger.
Safety symbols used in these Instructions for Use
These Instructions for Use use a number of warnings for risks and hazards that
might occur when using the device. These warnings contain signal words, which
will alert you to the degree of hazard you may encounter. These signal words
and corresponding hazards are as follows:
1)
The Technical Handbook, the Instructions for Use/data sheets of the sensors used, and the PC
software CC-Vision for Dräger X-am 5000, are included on CD. See also attached Instructions
for Use and Data Sheets of the sensors used.
®
2)
DrägerSensor
is a registered trademark of Dräger.
Indicates an imminently hazardous situation which, if not avoided, will result in
death or serious injury.
Indicates an imminently hazardous situation which, if not avoided, could result
in injury or damage to property.
1)
Can also be used to warn against any wanton actions.
Additional information for the use of the device.
1)
may
Intended use
Portable gas measuring device for the continuous monitoring of the
concentration of several gases in the ambient air in the working area and in
explosion-hazard areas.
Independent measurement of up to five gases, in accordance with the Dräger
sensors installed.
Areas subject to explosion hazards, classified by zones
The device is intended for use in explosion-hazard areas or mines, in which
firedamp classified by zone 0, zone 1 or zone 2 may occur. It is determined for
use within a temperature range of –20 °C to +50 °C, and for areas in which
gases of explosion groups IIA, IIB or IIC and temperature class T3 or T4
(depending on the batteries and rechargeable battery) may be present. For
zone 0, the temperature class is limited to T3.
If used in mines, the device is only to be used in areas known to have a low risk
of mechanical impact.
Areas subject to explosion hazards, classified by divisions.
The device is intended for use in explosion-hazard areas or mines, in which
firedamp classified by class I&II, Div. 1 or Div. 2 may occur.
It is determined for use within a temperature range of –20 °C to +50 °C, and for
areas in which gases or dusts of groups A, B, C, D or E, F, G, and temperature
class T3 or T4 (depending on the batteries and rechargeable battery) may be
present.
WARNING
CAUTION
NOTICE
11