10, 11, 12, 13 clamps for remote control
The remote control supplied is attached to this clamp block.
Clamp 10 +12 V/DC attachment clamp (this clamp is protected by a
750 mA fuse) (+)
Clamp 11 Ground clamp (-)
Clamp 12 Clock clamp CLK
Clamp 13 Data clamp DATA
14 Microphone connection
Connect this clamp to the "MIC" attachment clamp on the control panel.
15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25 and 26 alarm zones
Alarm sensors are connected to these clamps. There must be 2.2 kΩ resistance between the ground clamp
and the loop. If the loop recognises a change in the resistance value (contact interrupted (NC-contact
opens) = the value becomes infinite / resistance is bridged (NO-contact closes) = value becomes 0 Ω).
You should use a 2, 4 or 6-lead rigid telephone line for the connection. Maximum cable length
should not exceed 250 metres.
Clamp 15 Loop 1
Clamp 16 Ground clamp
Clamp 17 Loop 2
Clamp 18 Loop 3
Clamp 19 Ground clamp
Clamp 20 Loop 4
Clamp 21 Loop 5
Clamp 22 Ground clamp
Clamp 23 Loop 6
Clamp 24 Loop 7
Clamp 25 Ground clamp
Clamp 26 Loop 8
98
(+)
(-)
CLK DATA TAMPER NC