UDR
UDR receiver technical characteristics
UDR
5.5- UDR
UDR
Mechanical and environment withstand characteristics
Housing
Weight
Dimensions
Operating temperature range
Storage temperature range
Cable lead-outs
Connection
Radio characteristics
Characteristics complying with ETS 300 220
Reception frequency
(see list in appendix)
Antenna
(BNC plug-in type)
Sensitivity
Electrical characteristics
Power supply and consumption
(2)
(with 2 safety relays and 8 control
relays pulled in, and 3 UDF
modules connected to receiver)
Control
Safety
Response time
Active shutdown time
Passive shutdown time
Indicator lights
Protections
(1) = UDF infrared modules are delivered with 1 M16 plastic cable gland
(2) = The number of function relays controlled simultaneously is limited to 10 relays with 1 UDF
module connected to UDR receiver, or to 9 relays with 2 UDF modules connected, or to 8 relays
with 3 UDF modules connected.
A large label in the housing cover gives the following information to facilitate configuration and
maintenance of the UD system :
-
connection point numbers
-
wiring indication
-
fuse characteristics
-
indicator light functions
-
table showing the "Buttons/Relays/Functions" configurations for the application and the
interlocking configuration.
FR
EN
- 98 -
ABS, Grey - IP65
2 kg (approx.)
160x250x120 mm (without antenna and cable gland)
- 20°C to + 50°C
- 30°C to + 70°C
Power supply : 1 M16 caps (Ø 5 to 7 mm cables)
UDF module wiring : 3 M16 caps (Ø 5 to 7 mm cables) (1)
Control outputs : 1 M32 plastic cable gland (Ø 20 to 26 mm cables )
Spring-type terminal strips for 0.08² to 2.5² section wires
64 programmable UHF channels in 433-434 MHz bands
or 12 programmable UHF channels in 869 MHz band
or 64 programmable UHF channels in 911-918 MHz bands
ref: VUB084, 1/4 wave for 433-434MHz bands
ref: VUB086 , 1/2 wave for 869MHz band
ref: VUB984 , 1/2 wave for 911-918MHz bands
< -100dBm
DC version :
12VDC, 0 to +25%, 675mA and 188mA when idle
24VDC, -15% to +20%, 675mA and 188mA when idle
AC version n°1 :
24VAC, -15% to +10%, 850mA
48VAC, -15% to +10%, 400mA
AC version n°2
115VAC, -15% to +10%, 180mA
230VAC, -15% to +10%, 85mA
1 "Horn" relay and 6,12 or 18 function relays
2 safety relays with linked and guided contacts
On start-up : 0,5s max.
On control : 55 ms max.
145 ms max.
1,1 s max.
1 red indicator light "power on"
1 red + 1 green indicator lights for diagnostic
1 red indicator light for relay status
Power supply :
Against polarity inversions for DC versions
Against overcurrents by fuse
DE
UD - 319472K