UDB2 Battery pack technical characteristics
5.6- UDB2
UDB2
Mechanical, functional and environmental characteristics
Housing
Dimensions
Storage temperature range
Charging temperature range
Complete slow charging time
Indicator lights
Charging voltage
5.6.1- Battery pack storage precaution and general information
UDB2 battery pack must be stored charged in a proper and dry area with specified temperature
range on above table.
Self-discharge is estimated at 15% the first month and then low (it is mandatory to recharge
the battery pack every 6 months mini.). The number of full charge cycles is 500 minimum
(without damaging the battery pack capacity).
5.6.2- Precaution when inserting battery pack in transmitter unit
Whenever changing the battery pack, check that it is
properly secured in its housing in the back of the
transmitter.
If not, a type 5 fault caused by power supply micro-
cutouts can occur (following fault list generated by
the transmitter)
FR
EN
- 102 -
ABS Choc, yellow, plug-in
IP40
40x96x23 mm
-30°C to +35°C
0°C to +45°C
14 hours
Charging : 1 red light indicator on battery pack
Charge status : 1 red light indicator on transmitter
10 to 30 VDC