Udr Receiver; Udf Infrared Module (For Option "Starting Up By Infrared Validation") - Jay Electronique UD Série Notice Technique D'installation Et D'utilisation

Masquer les pouces Voir aussi pour UD Série:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

2.3.2- Receiver UDR
Number of outputs :
A = 6 function relays (1 relay board installed)
B = 12 function relays (2 relay boards installed)
C = 18 function relays (3 relays boards installed)
(the receiver UDR is systematically equipped with :
2 safety relays + 1 "Horn" relay)
U D R
Power supply :
4 = 12 - 24 VDC
A = 24 - 48 VAC
B = 115 - 230 VAC
Radio bands and version :
0 = Radio 433-434MHz
1 = Radio 433-434MHz + "starting up with IR validation" option (2)
A = Radio 869MHz
B = Radio 869MHz + "starting up with IR validation" option (2)
E = Radio 911-918MHz
F = Radio 911-918MHz + "starting up with IR validation" option (2)
(1) = A technical manual is supplied for certain additional options
(2) = This only includes the required programming for the receiver.
The UDF IR modules must be ordered separately.
Example : UDR0BB00-112
- UDR radio receiver 433-434MHz,without IR start-up validation, 3+12 relays, power supply:
115-230VAC, without programmed interlocking, without BPDV on transmitter, COM3/COM3R
or BPTR of the transmitter are : 1/OFF/2.
2.3.3- Infrared module UDF
(for «starting up by infrared validation» option)
The number of module to be ordered is in function of the equipment starting up area, up to 3
UDF modules can be connected to UDR receiver.
Each UDF module is delivered with 1 M16 plastic cable gland, a 10m extension cable and a
mounting bracket.
FR
EN
- 64 -
Additional option (1) :
0 = standard
2 = "Horn n°2"
3 = "coupled travelling cranes"
4 = "Micro-speed"
5 = "travelling crane transfer"
6 = "Transmitter-Receiver association at start-up"
-
0
Programming of transmitter BPSV and
BPDV button interlocking :
0 = no interlocking or COM (switch) on each row
1 = interlocking button n°1-n°2, n°-n°4, n°5-n°6
with output relays set to OFF
2 = interlocking button n°1-n°2, n°-n°4, n°5-n°6
with priority on left button
3 = interlocking button n°1-n°2, n°-n°4, n°5-n°6
with priority on right button
x = special (equipment definition covered by a
customization data sheet)
U D F
DE
Programming of button - relay correspondence :
Number of relays controlled by BPDV (double speed
pushbutton)
1 = 3 relays or no BPDV on transmitter
2 = 4 relays
x = special (equipment definition covered by a customization
data sheet)
Programming button - relay correspondence :
Type of control for COM3,COM3R and BPTR (switches
with 3 positions) on transmitter
1 = Type : 1/1+2/2 or no COM3/3R/BPTR on transmitter
2 = Type : 1/OFF/2
3 = Type : 1/2/1+2
x
=
special
customization data sheet)
Kit version :
1 = 1 infrared module
2 = 2 infrared modules
(equipment
definition
covered
UD - 319472K
by
a