Commissioning; Precautions When Commissioning; Periodic Checks And Checks Performed Following Maintenance Operations - Jay Electronique UD Série Notice Technique D'installation Et D'utilisation

Masquer les pouces Voir aussi pour UD Série:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

3-

Commissioning

3.1- Precautions when commissioning

The installer must :
- ensure that the transmitter and receiver identity code and radio channel match correctly,
- ensure that the radio channel chosen corresponds to the frequency plan set up for the site,
- perform a final check to verify that the desired Button-Relay correspondence is in place.
During the previous check, the installer must check that when the "On/Horn" button is pressed
on startup, only the function relays assigned to the rotary button selections are in the "ON"
state.
Verify the priority general shutdown mode (remote control in operation and radio link
established)::
Active stop :
Passive stop : When the electronic key is removed from the transmitter in operation, the
"Dead man" function duration :
Check the effective duration of the "Dead man" function (automatic shutdown of transmitter) :
Start up the remote control and leave it without activating any control. Record the time after
which the receiver safety relays (RS1 and RS2) are deenergized and check that this duration
corresponds to the standard duration supplied (4min.) or the duration specified on order
(special programming, see customisation sheet), or to the new duration defined by a trained
and authorized operator in accordance with the procedure described in chapter «transmitter
configuration».
Radio range limits and infrared range limit if option "start up with IR validation" chosen:
Evaluate the range limit of the transmitter/receiver assembly (by moving up to the range limit).
Make sure of the good infrared area covering by the IR module.
Special function: masking of certain function buttons :
If button masks are included in the electronic key, check that they properly correspond to the
application for which they have been provided.
3.2- Periodic checks and checks performed following
maintenance operations
In addition to the commissioning checks which should be performed, also check :
-
That the ergonomic features of the transmitter unit have been preserved, such as: pressure on
function buttons, correct rotation of rotary switches, correct functionning of emergency stop
button, etc.
-
Response time of commands between transmission of a command and resulting movement.
UD - 319472K
When the stop palmswitch button on the transmitter is pressed, the receiver
safety relays (RS1 and RS2) should instantaneously change state.
receiver safety relays (RS1 and RS2) should change state within two seconds
max.