Télécharger Imprimer la page

HumanTechnik A-3310-0 Mode D'emploi page 18

Dispositif vibrant

Publicité

Les langues disponibles

Les langues disponibles

Connecting the vibrating contraption:
The Humantechnik vibrating contraption is available in 2 variations:
Model A-3310-0 for direct connection to Humantechnik alarm clocks:
This variant has two cables: One alarm clock connection lead with a 3.5 mm jack
plug and one mains cable with a mains adapter.
Connect the alarm clock connection lead to the AUX output of the alarm clock.
Plug the adapter into a standard wall outlet.
The vibrating contraption is now ready for use.
Note: Other Humantechnik devices, such as some receivers of the »lisa« and
»signolux« alerting systems, as well as telephones and other detectors such as
»iBell2« and »Mona«, also have AUX outputs to which the vibrating contraption
can be connected.
Model A-3311-0 for connection to timed switches:
This variant has only one cable: a lead with a plug-in power supply unit.
Plug the mains adapter into the socket of the timer. Set the timer according to the
instructions of the respective manufacturer. App-controlled switching plugs can
also be used.
The vibration system is now ready for use.
Note: Make sure that the time for which it is switched on is not too long!
It is imperative that you observe the following section »Overload protection«.
Overload protection
The vibrating contraption is equipped with an electronic safety measure that pro-
tects the device from overload. This precaution expresses itself as follows:
After half an hour of continuous operation, the vibrating contraption enters a pha-
se in which it alternately vibrates for a ½ second and pauses for 2 seconds. This
phase ends after 1 hour, after which the vibration system switches itself off and a
reset is required.
Attention:
For the alarm clock version A-3310-0 merely a new signal of the alarm clock is
sufficient for the reset and thus the further operation of the system.
For the timer version A-3311-0, the mains plug must be disconnected from the
power for at least 10 seconds before the system can be put back into operation.
18 English

Publicité

loading

Ce manuel est également adapté pour:

A-3311-0