Indicators - Cristec HPOWER 12V/90A Manuel Utilisateur

Masquer les pouces Voir aussi pour HPOWER 12V/90A:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

3.4.7 Indicators

The following led indicators are visible on the front of the appliance for monitoring.
INDICATORS
GREEN LED
"On"
ORANGE LED
"Boost "
ORANGE LED
"Absorption"
GREEN LED
"Floating"
GREEN LED
"Refresh"
ORANGE LED
"Com"
RED LED "Fault"
STATE
On
Charger is ON
No or poor quality AC current
Input fuse is blown
Off
Internal charger malfunction
Charger in BOOST phase
Blinking
(switch E = '1')
Charger in ABSORPTION phase
On
(switch E = '1')
On
Charger in FLOATING phase
Charger in REFRESH phase
Blinking
(switch F = '1')
Blinking
Communication is running (LIN Bus or CAN Bus)
Charger abnormal operation:
Output short-circuit ;
-
The Charger voltage (before distribution) is below 11V ± 5%
-
(for 12V models) or 22V ± 5% (for 24V models) for more than
On
10 seconds (active during Floating phase only) ;
Battery temperature probe is < -10°C or > 50°C ;
-
Failure of fan.
-
MEANING