I
3.4
NTERFACES AND ACCESSORIES
J1201 et J102 :
CAN Bus
3.4.1 Temperature compensation
STP-HPO-2.8 and STP-HPO-5.0 temperature probes enable the compensation of Absorption voltage and
Floating Voltage depending on the ambient temperature of the battery room.
The coefficient used is -18mV/°C for 12V model and -36mV/°C for 24V models.
Temperature is not compensated when Wintering (or standby sealed bat), Stabilized DC power supply and Lithium
Iron Phosphate (LiFePO4) with BMS settings are selected
3.4.2 CAN Bus
The battery charger offers two receptables matching with connectors Molex Microfit 3.0, 6 circuits (reference 43025-
0600).
Documentation n°1512940REGA (hardware and software specification)
Is available upon request.
X1200 : CRISTEC LIN Bus :
- Remote display (HPO-DISPLAY-R)
- Parallel operation control
-
.
X1201 : Battery
temperature probe
37