Thermal Derating - Cristec HPOWER 12V/90A Manuel Utilisateur

Masquer les pouces Voir aussi pour HPOWER 12V/90A:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

REFRESH phase :
It is an automatic weekly cycle (Inhibited or not by means of switch F) in order to optimize the battery life duration.
It will occur only after a complete recharge cycle (BOOST, ABSORPTION and FLOATING).The charger will generate
automatically a safe timed voltage step every 7 days whatever the position of BOOST switch.
Phase REBOOST :
Automatic phase consisting in coming back to a BOOST voltage if the DC utilizations require it (i.e. after a complete
recharge cycle BOOST, ABSORPTION and FLOATING if a some DC constant consumptions are detected the charger
will restart a new complete charge cycle including a BOOST phase).
This REBOOST phase will be authorized after measuring certain battery voltage during a determined time.
BOOST in OFF position
With this setting, the CDS4 charger produces a single-stage UI type charge curve. It generates a constant voltage,
supplying the current required by the battery(ies). Recharging time depends on the state of the battery, and is longer
than when the BOOST is in the ON position.

3.4.6 Thermal derating

The curve below presents the power derating according to ambient temperature and AC input voltage :
Ve = 230Vac
Ve = 115Vac
Ve < 95Vac
%Pn: Percent of battery charger's rated output power.
41