TECHNICAL DATA
MODEL
TYPE
OUTPUT
(1)
DELIVERY
(1)
(According to EN 267)
OUTPUT
(1)
DELIVERY
(1)
(According to LRV '92)
FUEL
- Net calorific value
- Density
- Viscosity at 20 °C
OPERATION
NOZZLES
STANDARD APPLICATIONS
AMBIENT TEMPERATURE
COMBUSTION AIR TEMPERATURE
ELECTRICAL SUPPLY
ELECTRIC MOTOR
Running current
Start-up current
MOTOR CAPACITOR
IGNITION TRASFORMER
CONTROL BOX
PUMP SUNTEC AT 2 55 C
ELECTRICAL POWER CONSUMPTION
ELECTRICAL PROTECTION
IN CONFORMITY WITH EEC DIRECTIVES
NOISE LEVELS
(2)
APPROVAL
(1) Reference conditions: Ambient temperature 20°C - Barometric pressure 1000 mbar - Altitude 100 m a.s.l.
(2) Sound pressure measured in manufacturers combustion laboratory, with burner operating on test boiler and at maximum rated output.
ACCESSORIES
(optional):
•
DEGASSING UNIT
It may occur that a certain amount of air is contained in the light oil sucked up by the pump. This air may originate from the light oil itself as a
consequence of depressurization or air leaking past imperfect seals.
In double-pipe systems, the air returns to the tank from the return pipe; in single-pipe systems, the air remains in circulation causing pressure var-
iations in the pump and burner malfunctions.
For this reason, we advise installing a degassing unit near the burner in single-pipe installations.
Degassing units are provided in two versions:
CODE 3010054 without filter
CODE 3010055 with filter
- Burner delivery
: 80 kg/h max
- Light oil pressure
: 0.7 bar max
- Ambient temperature
: 40 °C max
- Light oil temperature
: 40 °C max
- Attachment connectors
: 1/4 inch
2nd stage
(high pressure)
1st stage
(low pressure)
2nd stage
(high pressure)
1st stage
(low pressure)
delivery (at 12 bar)
pressure range
fuel temperature
RL 22 BLU
964 T
kW
116 - 261
Mcal/h
100 - 224
kg/h
9.8 - 22
kW
89 - 178
Mcal/h
76,5 - 153
kg/h
7.5 - 15
kW
130 - 249
Mcal/h
112 - 214
kg/h
11 - 21
kW
95 - 178
Mcal/h
82 - 153
kg/h
8 - 15
Light oil
kWh/kg
11,8
Mcal/kg
10,2 (10.200 kcal/kg)
3
0,82 - 0,85
kg/dm
6 (1,5 °E - 6 cSt)
2
mm
/s max
• Intermittent (min. 1 stop in 24 hours)
• Two-stage (high and low flame) and single-phase (all - nothing)
numer
1
Boilers: water, steam, diathermic oil
°C
0 - 40
°C max
60
~ 50 Hz 230V +/- 10%
rpm
W
V
A
A
µF/V
V1 - V2
I1 - I2
kg/h
bar
°C max
W max
600
IP 44
89/336 - 73/23 - 92/42 - 98/37
dBA
71
0036 0308/01 (EN 267 class 3 NOx ≤ 120 mg/kWh)
CE
7
RL 32 BLU
965 T
228 - 356
196 - 306
19.2 - 30
166 - 249
143 - 214
14 - 21
237 - 356
204 - 306
20 - 30
166 - 249
143 - 214
14 - 21
2800
420
220 - 240
2,9
11
12.5/450
230 V - 2 x 5 kV
1,9 A - 30 mA
Landis & Gyr LOA 24...
60
4 - 25
60
600
72