Connection of safety transmitter-receiver photocells in closing (SG.C) with testing
Connection of safety transmitter-receiver photocells in opening (SG.A) with testing
We recommend installing opening and closing
safety photocells.
1 Complete the connections as shown in the figure.
2 Place DIP9 in ON (closing photocell enabled testing).
O
If the photocells are not connected to carry out
testing, place DIP9 in OFF.
O
If a magnetic strip is installed instead of a photocell,
place DIP9 in OFF.
O
If neither photocells nor a mechanical strip are
connected, make an electrical bridge between the
COM and SG.C cable connectors and place DIP9 in
OFF.
We recommend installing opening and closing
safety photocells.
1 Complete the connections as shown in the figure.
2 Place DIP6 in ON (opening photocell enabled
testing).
O
If the photocells are not connected to carry out
testing, place DIP6 in OFF.
O
If a magnetic strip is installed instead of a photocell,
place DIP6 in OFF.
O
If neither photocells nor a mechanical strip are
connected, make an electrical bridge between the
COM and SG.A cable connectors and place DIP6 in
OFF.
INSTALLATION
RINO operator for sliding gates
57