Les langues disponibles

Mount the magnetic limit switches
1 Move the gate manually to the opening position,
and position the opening magnet (1) with the
respective magnet-holder plate (2).
In the gate open position, the magnet (1) must
be opposite the magnetic opening limit switch
(reed) (3).
The distance between the magnets and the
operator frame must be at least 5 mm.
2 Move the gate manually to the closing position, and
position the closing magnet (4) with the respective
magnet-holder plate (5).
In the gate closed position, the magnet (4) must
be opposite the magnetic closing limit switch (reed)
(6).
The distance between the magnets and the
operator frame must be at least 5 mm.
3 Lock the operator using the handle (7).