F1
Sicherung Leitung 220/230 V 6,3 A
F2
Sicherung 24 V 1,6 A
Ld1
Leuchtdiode für das Vorhandensein von Stromspeisung
Ld2
Leuchtdiode Stop.
Ld3
CA Leuchtdiode Endanschlag Öffnen.
Ld4
CC Leuchtdiode Anzeige Endanschlag Schließen.
Ld5
CP Leuchtdiode für die Signalisierung Aktivität der Sicherheitsfühlleioste
TL
Leuchtdiode Anzeige Betriebszeit.
LED1
Leuchtdiode 24 V Netzspannung.
S1
Slot für Einschaalten der Empfängerkarte
TERMINALS CONNECTING TO THE K797M CONTROL CARD.
GB
1
earth connection
2-3
220-230 V ac 50/60 Hz power
4-5
220 V ac courtesy light output
5-6
220/230 V ac flashing output
7-8
Open/Close push button input (Normally Open contact): for instructions for use see functions of dip
switches n° 2; 7=Common
7-9
Stop push button contact NC (Normally Closed). After stopping the unit restarts opening and only after
a command given by the start push button or by the radio transmitter; 7=Common
7-10
Pneumatic edge input or other protection devices such as the photoelectric cells (NC contact);
7=Common
11-12
24 V ac output to power safety devices and/or other devices (photoelectric cells, pneumatic edge,
relays for lights, etc.)
13-14
Radio aerial input: 14=shield; 13=central
15-17
limit switch closing input (Normally Closed contact) 17=Common
16-17
limit switch opening input (Normally Closed contact) 17=Common
18-19
2nd radio channel output
20
earth connection
21-22-23
motor output ; 23=opening phase; 21=closing phase; 22=Common.
In the case of the B1 B1L series it is possible to connect a second geared motor in parallel
ATTENTION:
For each pair of terminals leading to a NC contact that is not being used, it will be necessary to carry out a short circuit so
as to guarantee that the card works normally.
The overhead garage door's earthing system must comply with current laws. The Manufacturer declines all responsibility
for damage arising from the non compliance with such laws.
LOGICAL ADJUSTMENTS
DIP SWITCHS
1
2
3
4
TL trimmer
TCA trimmer
on: when wide open the overhead swing door will close automatically after a certain length of
time set on the T.C.A. trimmer.
off: a specific command is needed to close the overhead swing door.
on: when the automation is working a sequence of opening and closing commands induces the
overhead swing door to OPEN-STOP-CLOSE-STOP-OPEN-STOP (step by step function).
off: in the same conditions the same sequence of commands induces the overhead swing door
to OPEN-CLOSE-OPEN-CLOSE, etc.
on: the overhead swing door functions as established by dip switch n° 2
off: the overhead swing door ignores the closing command when it is opening
not connected
Work time adjustment trimmer (0-120 seconds), that is, the time the overhead swing door takes
to make one whole manoeuvre. Counting starts with each command pulse. It is recommended to
adjust it with just a few seconds more than necessary.
Pause time adjustment trimmer (0-120 seconds), that is, the time the overhead swing door stays