STACKED WASHER/ELECTRIC DRYER INSTALLATION
REQUIREMENTS
Stacked Washer/Electric Dryer Electrical Requirements
This Washer/Dryer is supplied without an electric cord and plug.
It must be connected by a competent electrician to a single-
phase electricity supply at the voltage shown on the dataplate,
using a suitable fixed wiring installation in accordance with local
and national wiring regulations.
A 3-wire circular cord of minimum conductor size 4 mm
͜
cross-section area should be used.
A 25 A supply fuse should be used, and a switch having
͜
a contact separation in both poles that provides full
disconnection under over-voltage category III conditions
must be incorporated into the fixed wiring in accordance
with local wiring regulations. The Washer/Dryer should be
positioned so that the disconnection switch is clearly visible
and easily accessible to the user. This disconnection switch
also provides the function of an emergency stop control for
the user.
A cord clamp bush is provided on the Washer/Dryer, and
͜
should be tightened on completion of wiring. The electrical
mains terminals are located behind the small rear access
panel (terminal block cover), and connections should be
made in accordance with the terminal markings. Remember
to replace the terminal access panel (terminal block cover).
NOTE: In accordance with the European EMC Directive
(2014/30/EU), the maximum electrical supply system impedance
to which the electric dryer should be connected is declared to
be 0.054 Ohm + j0.034 Ohm.
NOTE: Electrical safety standards: The manufacturer has
chosen compliance with IEC/EN 60335 standards as the most
appropriate for this product.
14
This is 3-wire appliance which must be earthed.
2
If codes permit and an additional earth bond wire is used, it is
recommended that a qualified electrician determine that the
earth bond path is adequate.
Recommended Earthing Method
It is your responsibility to contact a qualified electrical installer
to ensure that the electrical installation is adequate and in
conformance with all local codes and ordinances.