STACKED WASHER/GAS DRYER INSTALLATION REQUIREMENTS
Stacked Washer/Gas Dryer Gas Supply Requirements
IMPORTANT: Observe all governing codes and ordinances.
In Australia and New Zealand, refer to AS/NZS 5601.1 – Gas
Installations.
Gas Supply
Before installation, check that the local gas distribution
conditions, nature of gas and pressure, and the adjustment of
the appliance are compatible. Burner information will be found
on the model/serial rating plate in the door recess of the dryer.
If this information does not agree with the type of gas available,
see your dealer.
Natural Gas:
This dryer is factory adjusted for use with NATURAL GAS (G20),
and no further adjustment should be required at installation.
L.P. Gas:
This dryer is also certified for use with L.P. gas with appropriate
conversion. No attempt shall be made to convert the appliance
from the gas specified on the model/serial rating plate for use
with a different gas without consulting the serving gas supplier.
Conversion must be done by a competent service technician.
L.P. Gas conversion kit for countries with 50 Hz power, except
for France and Belgium, part number W10571757, is available
for purchase from your dealer. Gas conversion kit (Australia),
part number W10571729, is available for purchase from your
dealer. Full instructions are supplied with the kit.
12
Natural gas (France/Belgium):
This dryer is also certified for France/Belgium for use with G20/
G25 gases (20 mbar/25 mbar) with appropriate conversion. No
attempt should be made to convert this appliance from the gas
specified on the gas rating label for use with a different gas
without consulting the serving gas supplier. Gas conversion
must be done by a qualified gas service technician. Conversion
kit, part number (W10181947) is available for purchase from
your dealer. Full instructions are supplied with the kit.
Supply line requirements:
Provide a rigid gas supply line to the Washer/Dryer location.
It should be minimum 12.5 mm (1/2") ID. When acceptable to
the gas supplier and local codes, 10 mm (3/8") ID rigid supply
line may be used for lengths under 6.1 m (20'). Pipe-joint
compounds resistant to the action of L.P. gas must be used.
NOTE: For installation in Australia and New Zealand, refer
to AS/NZS 5601 for pipe sizing details. All piping is to be in
accordance with AS/NZS 5601.1 – Gas Installations.
Gas connection to the dryer itself should be made by means of
a flexible gas hose suitable for the appliance and gas category
in accordance with national installation regulations. If in doubt,
contact the gas supplier. It should be minimum 10 mm (3/8") ID.
A means of restraint should be used between the Washer/Dryer
and the wall to avoid straining of the rigid gas supply when the
Washer/Dryer is moved. An appropriate length of chain and a
wall hook is recommended.
The dryer gas inlet connection is a 3/8" NPT thread. An adapter
is supplied for conversion to standard ISO 228-1 thread
(3/8" BSP).
Check for leaks by using an approved noncorrosive
leak-detection solution. Bubbles will show a leak. Correct any
leak found. A pressure measurement tapping is provided on the
gas valve within the dryer, accessible after removal of the lower
front panel.
The dryer must be disconnected from the gas supply piping
system during any pressure testing of that system.